Product:
Region:
Date:
February 2026
3
What happened?
Between 00:15 and 06:05 UTC, 03 February 2026, a platform issue with Managed Identity for Azure resources impacted customers when trying to create, update, delete, or acquire tokens in the East US and West US regions. These errors impacted dependent services such as Azure Synapse Analytics, Azure Databricks, Azure Stream Analytics, Azure Kubernetes Service, Microsoft Copilot Studio, Azure Chaos Studio, Azure Database for PostgreSQL Flexible Servers, Azure Container Apps, and Azure AI Video Indexer.
This issue is now mitigated. An update with more information will be provided shortly
2
Impact statement: As early as 19:46 UTC on 2 February 2026, we became aware of an issue causing customers to receive error notifications when performing service management operations - such as create, delete, update, scaling, start, stop - for Virtual Machines (VMs) affecting multiple regions. These issues are also impacting services with dependencies on these service management operations - including Azure Arc Enabled Servers, Azure Batch, Azure Cache for Redis, Azure Container Apps, Azure DevOps (ADO), Azure Kubernetes Service (AKS), Azure Backup, Azure Load Testing, Azure Firewall, Azure Search, Azure Virtual Machine Scale Sets (VMSS), GitHub (see https://www.githubstatus.com/" class="wa-link-status">https://www.githubstatus.com/" target="_blank">https://www.githubstatus.com)..
Current status: We identified the root cause as a configuration change that unintentionally restricted public access to certain Microsoft‑managed storage accounts used to host virtual machine extension packages.
We have fully applied the mitigation across all affected regions and validated that impacted configurations have been successfully updated.
Customers should now see full recovery of service management operations, and dependent services have recovered as expected.
January 2026
27
During this incident, we temporarily used our public Azure Status page because it was taking too long to determine exactly which customers, regions, or services were affected. Since the issue has been mitigated and customers who were impacted can read relevant communications in Azure Service Health, this public post will be removed once the final PIR is published. For details on how this public Status page is used, refer to https://aka.ms/StatusPageCriteria
What happened?
Between 09:22 UTC and 16:12 UTC on 27 January 2026, and again between 11:14 UTC and 13:35 UTC on 29 January 2026, a platform issue resulted in an impact to the Azure OpenAI Service in the Sweden Central region. Impacted customers may have experienced HTTP 500/503 errors, failed inference requests, and/or issues with model deployment metadata. This issue also affected the Agent Service and other downstream AI Services dependent on Azure OpenAI in this region.
What went wrong and why?
The Azure OpenAI service uses Azure Managed Redis to cache metadata used for serving incoming requests. Caches expiring and being fetched from metadata service is a very normal part of operations.
However, during this incident, certain cache entries with a larger than usual payload and higher usage, triggered a faster refresh cycle than normal. This unusually high increase in requests to Redis resulted in cache responses slowing down significantly resulting in request timeouts.
As a result, the Azure OpenAI service ended up heavily querying the backend that stores metadata which eventually became overwhelmed. This resulted in the customer availability impact.
How did we respond?
- 09:22 UTC on 27 January 2026 – The issue was detected through service monitoring which is also when customers began to see intermittent availability issues were observed.
- 12:36 UTC on 27 January 2026 – Initiated mitigation to restart the IRM service on the Sweden Central clusters.
- 12:46 UTC on 27 January 2026 – Identified that Sweden Central cluster is seeing pods crashing with out-of-memory errors.
- 13:02 UTC on 27 January 2026 – Initiated mitigation workflow by scaling out nodes in the cluster to improve request handling and resilience.
- 15:30 UTC on 27 January 2026 – Started to increase the memory available in the pods to alleviate memory load on the cluster.
- 15:53 UTC on 27 January 2026 – Completed increase in memory in the pods to alleviate memory load on the cluster.
- 16:12 UTC on 27 January 2026 – Service(s) restored, and customer impact mitigated.
- 11:14 UTC on 29 January 2026 – Customer impact began again.
- 11:21 UTC on 29 January 2026 – We detected this issue when our internal service monitoring system upon observing an increase in error messages, reduced service performance, and occasional interruptions in results prompting our team to investigate.
- 12:07 UTC on 29 January 2026 – We identified that the cause of the issue appears to be system instability and memory pressure.
- 12:34 UTC on 29 January 2026 – To address the issue, we increased memory and pod capacity on the backend cluster supporting Sweden Central, which restored service availability and stabilized request handling.
- 13:35 UTC on 29 January 2026 – Services restored, and customer impact mitigated.
How are we making incidents like this less likely or less impactful?
- We have increased memory limits for service pods hosting the metadata services, to improve stability and prevent out-of-memory crashes. (Completed)
- We have scaled out the metadata service instances, to handle increased load and improve request resilience. (Completed)
- We have enhanced our monitoring and alerting across regions, to detect abnormal memory usage patterns more quickly. (Completed)
- We have initiated detailed investigations to identify and fix the factors contributing to the underlying resource exhaustion issues. (Estimated completion: February 2026)
- We are developing automation scripts and systems for regular pod management and mitigation, to maintain service stability. These measures collectively aim to improve service resilience and reduce both the frequency and severity of similar incidents in the future. (Estimated completion: February 2026)
- We are rolling out an optimization to cache refresh concurrency behavior, that will limit load to backend services, while improving performance. (Estimated completion: February 2026)
This is our Preliminary PIR to share what we know so far. After our internal retrospective is completed (generally within 14 days) we will publish a Final PIR to Azure Service Health with additional details.
How can customers make incidents like this less impactful?
- Consider managing endpoints in multiple regions, to enable the ability to failover in case the primary region is ever unavailable. For guidance on Business Continuity and Disaster Recovery (BCDR) scenarios, review https://learn.microsoft.com/azure/ai-services/openai/how-to/business-continuity-disaster-recovery
- More generally, consider evaluating the reliability of your applications using guidance from the Azure Well-Architected Framework and its interactive Well-Architected Review: https://aka.ms/AzPIR/WAF
- The impact times above represent the full incident duration, so are not specific to any individual customer. Actual impact to service availability varied between customers and resources – for guidance on implementing monitoring to understand granular impact: https://aka.ms/AzPIR/Monitoring
- Finally, consider ensuring that the right people in your organization will be notified about any future service issues – by configuring Azure Service Health alerts. These can trigger emails, SMS, push notifications, webhooks, and more: https://aka.ms/AzPIR/Alerts.
How can we make our incident communications more useful?
- You can rate this PIR and provide any feedback using our quick 3-question survey: https://aka.ms/AzPIR/BMVM-7_G
December 2025
22
Watch our 'Azure Incident Retrospective' video about this incident: https://aka.ms/air/FV31-PQG
What happened?
Between 08:05 UTC and 18:30 UTC on 22 December 2025, the Microsoft Entra Privileged Identity Management (PIM) service experienced issues that impacted role activations for a subset of customers. Some requests returned server errors (5xx) and, for a portion of customers, some requests returned unexpected client errors (4xx). This issue manifested as API failures, elevated latency, and various activation errors.
Impacted actions could have included:
- Reading eligible or active role assignments
- Eligible or Active Role assignment management
- PIM Policy and PIM Alerts management
- Activation of Eligible or Active Role assignments
- Deactivation of role assignments initiated by customer (deactivations triggered by the expiration of previous activation were not impacted)
- Approval of role assignment activation or extension
Customer initiated PIM operations from various Microsoft management portals, mobile app, and API calls were likely impacted. During this incident period, operations that were retried may have succeeded.
What went wrong and why?
Under normal conditions, Privileged Identity Management processes requests—such as role activations—by coordinating activity across its front-end APIs, traffic routing layer, and the backend databases that store role activation information. These components work together to route requests to healthy endpoints, complete required checks, and process activations without delay. To support this flow, the system maintains a pool of active connections for responsiveness and automatically retries brief interruptions to keep error rates low, helping ensure customers experience reliable access when reading, managing, or activating role assignments.
As part of ongoing work to improve how the PIM service stores and manages data, configuration changes which manage the backend databases were deployed incrementally using safe deployment practices. The rollout progressed successfully through multiple rings, with no detected errors and all monitored signals remaining within healthy thresholds.
When the deployment reached a ring operating under higher workload, the additional per-request processing increased demand on the underlying infrastructure that hosts the API which manages connections to the backend databases. Although the service includes throttling mechanisms designed to protect against spikes in API traffic, this scenario led to elevated CPU utilization without exceeding request-count thresholds, so throttling did not engage. Over time, the sustained load caused available database connections to be exhausted, and the service became unable to process new requests efficiently. This resulted in delays, timeouts, and errors for customers attempting to view or activate privileged roles.
How did we respond?
- 21:36 UTC on 15 December 2025 – The configuration change deployment was initiated.
- 22:08 UTC on 19 December 2025 – The configuration change was progressed to the ring with the heavy workload.
- 08:05 UTC on 22 December 2025 – Initial customer impact began.
- 08:26 UTC on 22 December 2025 – Automated alerts received for intermittent, low volume of errors prompting us to start investigating.
- 10:30 UTC on 22 December 2025 – We attempted isolated restarts on impacted database instances in an effort to mitigate low-level impact.
- 13:03 UTC on 22 December 2025 – Automated monitoring alerted us to elevated error rates and a full incident response was initiated.
- 13:22 UTC on 22 December 2025 – We identified that calls to the database were intermittently timing out. Traffic volume appeared to be normal with no significant surge detected however we observed the spike in CPU utilization.
- 13:54 UTC on 22 December 2025 – Mitigation efforts began, including beginning to scale out the impacted environments.
- 15:05 UTC on 22 December 2025 – Scale out efforts were observed as decreasing error rates but not completely eliminating failures. Further instance restarts provided temporary relief.
- 15:25 UTC on 22 December 2025 – Scaling efforts continued. We engaged our database engineering team to help investigate.
- 16:37 UTC on 22 December 2025 – While we did not correlate the deployment to this incident, we initiated a rollback of the configuration change.
- 17:20 UTC on 22 December 2025 – Scale-out efforts completed.
- 17:45 UTC on 22 December 2025 – Service availability telemetry was showing improvements. Some customers began to report recovery.
- 18:30 UTC on 22 December 2025 – Customer impact confirmed as mitigated, after rollback of configuration change had completed and error rates had returned to normal levels.
How are we making incidents like this less likely or less impactful?
- We have rolled back the problematic configuration change across all regions. (Completed)
- For outages that manifest later as a result of configuration updates, we are developing a mechanism to help engineers correlate these signals more quickly. (Estimated completion: January 2026)
- We are working to ensure this configuration change will not inadvertently introduce excessive load before we redeploy this again. (Estimated completion: January 2026)
- We are working on updating our auto-scale configuration to be more responsive to changes in CPU usage. (Estimated completion: January 2026)
- We are enabling monitoring and runbooks for available database connections to respond to emerging issues sooner. (Estimated completion: February 2026)
How can customers make incidents like this less impactful?
- Consider retrying critical operations directly through the API, for example, when requesting just in time access: https://learn.microsoft.com/entra/id-governance/privileged-identity-management/pim-apis#iteration-3-current--pim-for-microsoft-entra-roles-groups-in-microsoft-graph-api-and-for-azure-resources-in-azure-resource-manager-api
- More generally, consider evaluating the reliability of your applications using guidance from the Azure Well-Architected Framework and its interactive Well-Architected Review: https://aka.ms/AzPIR/WAF
- The impact times above represent the full incident duration, so are not specific to any individual customer. Actual impact to service availability varied between customers and resources – for guidance on implementing monitoring to understand granular impact: https://aka.ms/AzPIR/Monitoring
- Finally, consider ensuring that the right people in your organization will be notified about any future service issues – by configuring Azure Service Health alerts. These can trigger emails, SMS, push notifications, webhooks, and more: https://aka.ms/AzPIR/Alerts
How can we make our incident communications more useful?
You can rate this PIR and provide any feedback using our quick 3-question survey: https://aka.ms/AzPIR/FV31-PQG
8
What happened?
Between 11:04 and 14:13 EST on 08 December 2025, customers using any of the Azure Government regions may have experienced failures when attempting to perform service management operations through Azure Resource Manager (ARM). This included operations attempted through the Azure Portal, Azure REST APIs, Azure PowerShell, and Azure CLI.
Affected services included but were not limited to: Azure App Service, Azure Backup, Azure Communication Services, Azure Data Factory, Azure Databricks, Azure Functions, Azure Kubernetes Service, Azure Maps, Azure Migrate, Azure NetApp Files, Azure OpenAI Service, Azure Policy (including Machine Configuration), Azure Resource Manager, Azure Search, Azure Service Bus, Azure Site Recovery, Azure Storage, Azure Virtual Desktop, Microsoft Fabric, and Microsoft Power Platform (including AI Builder and Power Automate).
What went wrong and why?
Azure Resource Manager (ARM) is the gateway for management operations for Azure services. ARM does authorization for these operations based on authorization policies, stored in Cosmos DB accounts that are replicated to all regions. On 08 December 2025, an inadvertent automated key rotation resulted in ARM failures to fetch authorization policies that are needed to evaluate access. As a result, ARM was temporarily unable to communicate with underlying storage resources, causing failures in service-to-service communication and affecting resource management workflows across multiple Azure services. This issue surfaced as authentication failures and 500 Internal Server errors to customers across all clients. Because the content of the Cosmos DB accounts for authorization policies is replicated globally, all regions within the Azure Government cloud were affected.
Microsoft services use an internal system to manage keys and secrets, which also makes it easy to perform regular needed maintenance activities, such as rotating secrets. Protecting identities and secrets is a key pillar in our Secure Future Initiative to reduce risk, enhance operational maturity, and proactively prepare for emerging threats to identity infrastructure – by prioritizing secure authentication and robust key management. In this case, our ARM service was using a key in a ‘manual mode’ which means that any key rotations would need to be manually coordinated, so that traffic could be moved to use a different key before the key could be regenerated. The Cosmos DBs that ARM use for accessing authorization policies was intentionally onboarded to the Microsoft internal service which governs the account key lifecycle, but unintentionally configured with the option to automatically rotate the keys enabled. This automated rotation should have been disabled as part of the onboarding process, until such time as it was ready to be fully automated.
Earlier on the same day of this incident, a similar key rotation issue affected services in the Azure in China sovereign cloud. Both the Azure Government and Azure in China sovereign cloud had their (separate but equivalent) keys created on the same day, starting completely independent timers, back in February 2025 – so each was inadvertently rotated on their respective timers, approximately three hours apart. As such, the key used by ARM for the Azure Government regions was automatically rotated, before the same key rotation issue affecting the Azure in China regions was fully mitigated. Although potential impact to other sovereign clouds was discussed as part of the initial investigation, we did not have a sufficient understanding of the inadvertent key rotation to be able to prevent impact in the second sovereign cloud, Azure Government.
How did we respond?
- 11:04 EST on 08 December 2025 – Customer impact began.
- 11:07 EST on 08 December 2025 – Engineering was engaged to investigate based on automated alerts.
- 11:38 EST on 08 December 2025 – We began applying a fix for the impacted authentication components.
- 13:58 EST on 08 December 2025 – We began to restart ARM instances, to speed up the mitigation process.
- 14:13 EST on 08 December 2025 – All customer impact confirmed as mitigated.
How are we making incidents like this less likely or less impactful?
- First and foremost, our ARM team have conducted an audit to ensure that there are no other manual keys that are misconfigured to be auto-rotated, across all clouds. (Completed)
- Our internal secret management system has paused automated key rotations for managed keys, until usage signals are made available on key usage – see the Cosmos DB change safety repair item below. (Completed)
- We will complete the migration to auto-rotated Cosmos DB account keys for ARM authentication accounts, across all clouds. (Estimated completion: February 2026)
- Our Cosmos DB team will introduce change safety controls that block regenerating keys that have usage, by emitting a relevant usage signal. (Estimated completion: Public Preview by April 2026, General Availability to follow by August 2026)
How can customers make incidents like this less impactful?
- There was nothing that customers could have done to avoid or minimize impact from this specific service incident.
- More generally, consider evaluating the reliability of your applications using guidance from the Azure Well-Architected Framework and its interactive Well-Architected Review: https://aka.ms/AzPIR/WAF
- The impact times above represent the full incident duration, so are not specific to any individual customer. Actual impact to service availability varied between customers and resources – for guidance on implementing monitoring to understand granular impact: https://aka.ms/AzPIR/Monitoring
- Finally, consider ensuring that the right people in your organization will be notified about any future service issues – by configuring Azure Service Health alerts. These can trigger emails, SMS, push notifications, webhooks, and more: https://aka.ms/AzPIR/Alerts
How can we make our incident communications more useful?
You can rate this PIR and provide any feedback using our quick 3-question survey: https://aka.ms/AzPIR/ML7_-DWG
8
What happened?
Between 16:50 CST on 08 December 2025 and 02:00 CST on 09 December 2025 (China Standard Time) customers using any of the Azure in China regions may have experienced failures when attempting to perform service management operations through Azure Resource Manager (ARM). This included operations attempted through the Azure Portal, Azure REST APIs, Azure PowerShell, and Azure CLI.
Affected services included but were not limited to: Azure AI Search, Azure API Management, Azure App Service, Azure Application Insights, Azure Arc, Azure Automation, Azure Backup, Azure Data Factory, Azure Databricks, Azure Database for PostgreSQL Flexible Server, Azure Kubernetes Service, Azure Logic Apps, Azure Managed HSM, Azure Marketplace, Azure Monitor, Azure Policy (including Machine Configuration), Azure Portal, Azure Resource Manager, Azure Site Recovery, Azure Stack HCI, Azure Stream Analytics, Azure Synapse Analytics, and Microsoft Sentinel.
What went wrong and why?
Azure Resource Manager (ARM) is the gateway for management operations for Azure services. ARM does authorization for these operations based on authorization policies, stored in Cosmos DB accounts that are replicated to all regions. On 08 December 2025, an inadvertent automated key rotation resulted in ARM failures to fetch authorization policies that are needed to evaluate access. As a result, ARM was temporarily unable to communicate with underlying storage resources, causing failures in service-to-service communication and affecting resource management workflows across multiple Azure services. This issue surfaced as authentication failures and 500 Internal Server errors to customers across all clients. Because the content of the Cosmos DB accounts for authorization policies is replicated globally, all regions within the Azure in China cloud were affected.
Azure services use an internal system to manage keys and secrets, which also makes it easy to perform regular needed maintenance activities, such as rotating secrets. Protecting identities and secrets is a key pillar in our Secure Future Initiative to reduce risk, enhance operational maturity, and proactively prepare for emerging threats to identity infrastructure – by prioritizing secure authentication and robust key management. In this case, our ARM service was using a key in a ‘manual mode’ which means that any key rotations would need to be manually coordinated, so that traffic could be moved to use a different key before the key could be regenerated. The Cosmos DBs that ARM use for accessing authorization policies was intentionally onboarded to the internal service which governs the account key lifecycle, but unintentionally configured with the option to automatically rotate the keys enabled. This automated rotation should have been disabled as part of the onboarding process, until such time as it was ready to be fully automated.
How did we respond?
- 16:50 CST on 08 December 2025 – Customer impact began.
- 16:59 CST on 08 December 2025 – Engineering was engaged to investigate based on automated alerts.
- 18:37 CST on 08 December 2025 – We identified the underlying cause as the incorrect key rotation.
- 19:16 CST on 08 December 2025 – We identified mitigation steps and began applying a fix for the impacted authentication components. This was tested and validated before being applied.
- 22:00 CST on 08 December 2025 – We began to restart ARM instances, to speed up the mitigation process.
- 23:53 CST on 08 December 2025 – Many services had recovered but residual impact remained for some services.
- 02:00 CST on 09 December 2025 – All customer impact confirmed as mitigated.
How are we making incidents like this less likely or less impactful?
- First and foremost, our ARM team have conducted an audit to ensure that there are no other manual keys that are misconfigured to be auto-rotated, across all clouds. (Completed)
- Our internal secret management system has paused automated key rotations for managed keys, until usage signals are made available on key usage – see the Cosmos DB change safety repair item below. (Completed)
- We will complete the migration to auto-rotated Cosmos DB account keys for ARM authentication accounts, across all clouds. (Estimated completion: February 2026)
- Our Cosmos DB team will introduce change safety controls that block regenerating keys that have usage, by emitting a relevant usage signal. (Estimated completion: Public Preview by April 2026, General Availability to follow by August 2026)
How can customers make incidents like this less impactful?
- There was nothing that customers could have done to avoid or minimize impact from this specific service incident.
- More generally, consider evaluating the reliability of your applications using guidance from the Azure Well-Architected Framework and its interactive Well-Architected Review: https://aka.ms/AzPIR/WAF
- The impact times above represent the full incident duration, so are not specific to any individual customer. Actual impact to service availability varied between customers and resources – for guidance on implementing monitoring to understand granular impact: https://aka.ms/AzPIR/Monitoring
- Finally, consider ensuring that the right people in your organization will be notified about any future service issues – by configuring Azure Service Health alerts. These can trigger emails, SMS, push notifications, webhooks, and more: https://aka.ms/AzPIR/Alerts
How can we make our incident communications more useful?
You can rate this PIR and provide any feedback using our quick 3-question survey: https://aka.ms/AzPIR/JSNV-FBZ
November 2025
5
Watch our 'Azure Incident Retrospective' video about this incident: https://aka.ms/air/2LGD-9VG
What happened?
Between approximately 16:53 UTC on 5 November 2025 and 02:25 UTC on 6 November 2025, a subset of customers in the West Europe region experienced service disruptions or degraded performance across multiple services, including Virtual Machines (VM), Azure Database for PostgreSQL Flexible Server, MySQL Flexible Server, Azure Kubernetes Service, Storage, Service Bus, and Virtual Machine Scale Sets, among others. Customers using Azure Databricks in West Europe observed degraded performance when launching or scaling all-purpose and job compute workloads, which impacted Unity Catalog and Databricks SQL operations.
What went wrong and why?
The incident was triggered by a voltage sag in the utility grid, which caused cooling units to shut down and temperatures to rise above normal thresholds in a datacenter located in Physical Availability Zone 01 in the West Europe region. As temperature rose, multiple storage scale units automatically powered down to prevent hardware damage. Under normal circumstances, cooling systems are designed and commissioned to automatically restart after power events and are built with sufficient redundancy to maintain safe operating conditions even when failures occur. While cooling unit auto-restart capability had been regularly tested and exercised in this datacenter, the specific size and duration of utility sag exposed a previously unknown hardware issue that prevented the cooling units from restarting. This resulted in temperatures exceeding safe operational limits for infrastructure.
The extended recovery time was influenced by several factors. Recovery of storage scale units was prolonged because some storage servers entered a degraded state, necessitating sequential validation before they could be brought back online. In addition, dependent services such as compute and networking could not resume until storage integrity checks were complete. Finally, additional thermal audits were performed before workloads were reactivated to ensure that no residual risk remained.
How did we respond?
Automated monitoring detected the temperature anomaly and triggered an incident response. Facilities teams restored safe operating conditions by performing hard reset on the affected units and confirmed that temperatures were trending back to safe levels. Service recovery efforts began once the facility had reached safe operating temperatures.
Following this, storage systems initiated comprehensive data consistency checks when nodes in a storage scale unit restarted after the unplanned shutdown. These checks, which may include reconstructing replicas that have fallen behind. The recovery process prioritizes data integrity and durability over availability, resulting in customer traffic being blocked until all integrity validations was completed and contributing to the extended recovery time. In parallel, engineers prioritized recovery of compute hosts to stop further VM failures and allow dependent services to resume.
Timeline of events:
- 16:53 UTC on 5 November 2025 – Customer impact began as elevated temperatures caused multiple storage scale units to shut down.
- 16:55 UTC on 5 November 2025 – Datacenter monitoring detected temperature breaches and triggered thermal alerts.
- 17:20 UTC on 5 November 2025 – Power sag and cooling unit failure to restart identified as contributing factors. Cooling recovery begins as engineers manually restart cooling units.
- 17:40 UTC on 5 November 2025 – Mitigation workstream started as cooling restoration progresses.
- 17:48 UTC on 5 November 2025 – All cooling units restored, we start seeing temperatures reducing as cooling normalized.
- 17:50 UTC on 5 November 2025 – Rack-level thermal monitoring returned to safe operational thresholds. Engineering teams initiated storage recovery.
- 18:30 UTC on 5 November 2025 – Sequential storage scale unit validation began. Each scale unit underwent integrity checks to ensure no data corruption before bringing storage services back into rotation.
- 20:00 UTC on 5 November 2025 – Gradual restoration of storage scale units. Recovery was staged to avoid overloading power and cooling systems. Dependent compute nodes remained offline during this time.
- 23:30 UTC on 5 November 2025 – Service dependency checks and orchestration. Networking and compute services were progressively re-enabled after storage scale units passed health checks.
- 02:25 UTC on 6 November 2025 – All services were brought back online, and customer impact was mitigated.
How are we making incidents like this less likely or less impactful?
We are implementing several improvements to strengthen resilience and accelerate recovery:
- We are conducting internal and manufacturer-led forensic investigations of specific device hardware and firmware to develop solutions to bolster component tolerance to power sags and voltage fluctuations. (Estimated completion: December 2025)
- We are performing a gap analysis of the control circuit to ensure all relays delivering critical function of the units are powered through Uninterruptible Power Supply (UPS) and stored energy sources. (Estimated completion: January 2026)
- We are validating our maintenance procedures and adding additional prechecks for Heating, Ventilation, and Air Conditioning (HVAC) subsystems. (Estimated completion: January 2026)
- We are optimizing recovery steps for compute and storage systems to reduce overall restoration time. (Estimated completion: January 2026)
- We are improving automated correlation between environmental signals and service health to trigger earlier, and more targeted escalations. (Estimated completion: January 2026)
- We are updating our cooling unit commissioning playbooks to expand range of power sag and swell scenarios. (Estimated completion: February 2026)
- In the longer term, we are implementing a new approach to accelerate service restoration after major incidents. Historically, recovery prioritized full data integrity checks before bringing services online, which extended downtime because it was a serial process. Going forward, integrity checks will run in the background during VM and disk mount operations, allowing availability to return much sooner without compromising data safety. This change is a direct outcome of this incident and represents a significant improvement in recovery speed. (Estimated completion: April 2026)
How can customers make incidents like this less impactful?
- Consider using Availability Zones (AZs) to run your services across physically separate locations within an Azure region. To help services be more resilient to datacenter-level failures like this one, each AZ provides independent power, networking, and cooling. Many Azure services support zonal, zone-redundant, and/or always-available configurations: https://docs.microsoft.com/azure/availability-zones/az-overview
- Plan for regional redundancy by using active/active or failover designs across paired regions.
- Maintain regular backups and test failover procedures to ensure recovery readiness.
- Increase resilience by using retry logic and backoff strategies to prevent overload during recovery.
- More generally, consider evaluating the reliability of your applications using guidance from the Azure Well-Architected Framework and its interactive Well-Architected Review: https://aka.ms/AzPIR/WAF
- The impact times above represent the full incident duration, so are not specific to any individual customer. Actual impact to service availability varied between customers and resources – for guidance on implementing monitoring to understand granular impact: https://aka.ms/AzPIR/Monitoring
- Finally, consider ensuring that the right people in your organization will be notified about any future service issues – by configuring Azure Service Health alerts. These can trigger emails, SMS, push notifications, webhooks, and more: https://aka.ms/AzPIR/Alerts
How can we make our incident communications more useful?
You can rate this PIR and provide any feedback using our quick 3-question survey: https://aka.ms/AzPIR/2LGD-9VG