December 2021
9
Summary of Impact: Between approximately 21:00 UTC on 09 Dec 2021 and 00:23 UTC on 10 Dec 2021, a subset of customers using App Service and/or Azure Functions may have encountered issues with deployments using web deploy, managing WebJobs, connecting to Web SSH console, executing certain Diagnostic Tools using Azure portal or while accessing SCM endpoint. App Service resources utilizing other deployment methods were not affected. Standard App Service control plane operations and runtime were not impacted.
Root Cause: As part of introducing certain resiliency measures, a configuration change was implemented to create a redundant Domain Name Resolution zone for App Service SCM endpoints. However, due to a misconfiguration, this change incorrectly affected the name resolution for App Service SCM endpoint, which resulted in a subset of our customers not being able to connect to the SCM endpoints of the service. This misconfiguration was limited in scope to the SCM endpoint and no other data plane or control plane operations experienced any failures.
Mitigation: Engineering was engaged upon receiving reports of failure. In order to mitigate the issue, the misconfigured state of the zone was corrected and persisted for SCM endpoints. Most customers observed resolution within 20 - 40 minutes from when the mitigation was applied. Resolution times varied for customers depending on the Time To Live (TTL) setting of the various networking devices in their traffic pipelines.
Next Steps: We apologize for the impact to affected customers. We are continuously taking steps to improve the Microsoft Azure Platform and our processes to help ensure such incidents do not occur in the future. In this case, this includes (but is not limited to):
- Adding automated detection for SCM endpoint related failures.
- Adding improved validation for zone configuration updates.
- Enhancing review measures for critical network configurations.
Provide Feedback: Please help us improve the Azure customer communications experience by taking our survey: https://aka.ms/AzurePIRSurvey