Skip to Main Content

November 2022

2

What happened?

Between 00:42 UTC on 2 November and 05:55 UTC on 3 November 2022, customers experienced failures when attempting to provision new resources in a subset of Azure services including Application Gateway, Bastion, Container Apps, Database Services (MySQL - Flexible Server, Postgres - Flexible Server, and others), ExpressRoute, HDInsight, Open AI, SQL Managed Instance, Stream Analytics, VMware Solution, and VPN Gateway. Provisioning new resources in these services requires creating new certificates. The certificate Registration Authority (RA) that processes new certificate requests experienced a service degradation, which led to an incident preventing provisioning new resources in this subset of Azure services. We’re providing you with this Post Incident Review (PIR) to summarize what went wrong, how we responded, and the steps Microsoft is taking to learn and improve. Communications for this incident were provided under Tracking IDs YTGZ-1Z8 (Azure Public), 7LHZ-1S0 (Azure Government) and YTHP-180 (Azure China).

What went wrong, and why?

At 23:56 UTC on 1 November through 00:52 UTC on 2 November, an internal Certificate Authority (CA) experienced a brief service degradation. At the same time, the Registration Authority (RA) that sends requests to the CA received a burst of certificate renewal requests, resulting in requests queueing at the RA. Once the CA recovered, the request queue started processing. Due to a latent performance bug in the RA, inadvertently introduced in the past month as part of a feature enhancement, the rate of new incoming requests was greater than the rate at which requests could be processed from the queue. This triggered automatic throttling of incoming requests, but the RA was unable to recover fully due to throttled requests causing additional retry traffic. The latent performance bug was not caught during deployment or through health monitoring, due to a test gap where this specific set of conditions was not exercised. 

How did we respond? 

The issue was detected via our internal monitoring and the relevant engineering team was engaged within one minute of the alert firing. The service was unable to self-heal, so the following steps were taken to mitigate the incident. Firstly, we rolled back the change containing the performance bug. Secondly, we blocked requests to the RA, to enable the queue to drain. Finally, once the queue was at a manageable length, we re-enabled traffic slowly - and monitored service recovery until all traffic was re-enabled, and the RA had returned to a healthy state.

How are we making incidents like this less likely or less impactful?

  • We have increased processing capacity by 3x, for the RA backend component. (Completed)
  • We have introduced more granular request throttling, to help smooth similar spikes in traffic. (Completed)
  • We have extended our end-to-end service monitoring to include upstream request sources, to reduce time to detection. (Completed)
  • We are exploring more fine-grained throttling as an additional isolation layer across the backend of the RA (Estimated completion: December 2022).
  • We are deploying additional dedicated RA capacity for the Azure China and Azure Government cloud environments (Estimated completion: March 2023). 

How can we make our incident communications more useful?

You can rate this PIR and provide any feedback using our quick 3-question survey: