What happened? 

Between 16:10 and 19:55 UTC on 07 Sep 2022, a subset of customers using Azure Front Door (AFD) experienced intermittent availability drops, connection timeouts and increased latency. At its peak, this impacted approximately 25% of the traffic, and on average, 10% of the traffic that traverses through the AFD service during the impact window. Some customers may have seen higher failures if their traffic was concentrated in the edges or regions with higher impact. This could also have impacted customers’ ability to access other Azure services that leverage AFD, in particular the Azure management portal and Azure Content Delivery Network (CDN).

What went wrong and why? 

The AFD platform automatically balances traffic across our global network of edge sites. When there is a failure in any of our edge sites or an edge site becomes overloaded, traffic is automatically moved to other healthy edge sites in other regions where we have fallback capacity. It is because of this design that customers and end users don’t experience any issues in case of localized or regionalized impact. In addition to that, we also have protections built in every single node to protect our platform from unusual traffic spikes corresponding to each domain hosted on AFD.

 Between 15:15 and 16:44 UTC we observed 3 unusual traffic spikes for one of the domains hosted on AFD.

  • The first two spikes for this domain occurred at 15:15 UTC and 16:00 UTC on 07 of September, 2022 and were fully mitigated by AFD platform. A third spike that occurred between 16:10 to 16:44 caused a subset of environments managing this traffic to go offline.
  • The first two spikes were successfully absorbed due the platform protection mechanisms, however the ones that were initiated during the third spike did not fully mitigate the unexpected increase due to the nature of the traffic pattern (different from the first two spikes). At this stage in our investigation, we believe that all three traffic spikes were malicious HTTPS flood attacks. (Layer 7 volumetric DDOS attacks) 
  • The malicious traffic spikes did not originate from a single region. We found that they were coming from all around the world. A combination of malicious traffic (3rd spike), large traffic ramp-up for legitimate traffic for other customer and degraded customer origins, resulted in overwhelming the resources of a few environments taking them offline and resulting in a 25% drop in overall availability during the third traffic spike
  • By design, these environments will automatically recover and resume taking traffic once healthy. During this instance, users and our systems retried the requests, resulting in a larger build-up of requests. This build-up did not allow time for a subset of the environments to recover fully resulting in a subsequent 8% availability drop, for more than 3.5 hours following the traffic spike.

How did we respond? 

We have automatic protection mechanisms in such events which mitigate circa 2,000 DDoS attacks per day, and the record that we have mitigated in a day has been 4,296. (More information can be found here: ). In addition to this, AFD platform also has in-built DDoS protection mechanisms on each node at both a system and an application layer. These help for further mitigations in such cases. In this instance, these mechanisms significantly helped to absorb the first two spikes without any customer impact.

During the third spike, the platform protection mechanisms were partially effective, mitigating around 40% of the traffic. This significantly helped to limit global impact. For a larger duration, 8.5% of the overall AFD service, concentrated in some regions, was impacted by this issue. Some customers may have seen higher failures if their traffic was concentrated in predominantly North America, Europe, or the APAC regions.

 As our telemetry alerted us regarding impact on availability, we manually intervened. The first step was that we took manual action to further block the attack traffic. In addition, we expedited the AFD load balancing process which then enabled auto-recovery systems to work as designed. The systems worked by ensuring the most efficient load distributions in regions where there was a large build-up of traffic. Once the environment recovered, we began to gradually bring AFD instances back online to resume traffic management in a normal way. We were 100% globally recovered by 19:55 UTC.

How are we making incidents like this less likely or less impactful?

Although the AFD platform has built-in resiliency and capacity, we must continuously strive to improve through these lessons learned. We have a few previously planned repair items that were inflight being either partially deployed and/or staged to be deployed. We believe that these repair items would have mitigated the third malicious traffic spike had they been in place before Sept 7th. We are now expediting these repair items that were scheduled for later this year and they should be completed in the next few weeks. These include: 

  • Effectively tuning the protection mechanisms in the AFD nodes to mitigate the impact of this class of traffic patterns in future. (Estimated completion September 2022)
  • Addressing issues identified in the current platform environment recovery process. This will reduce time to recover for each environment and will prevent environments from becoming overloaded. (Estimated completion September 2022)
  • Tooling to trigger ‘per customer’ failover until we have fully automated the traffic shifting mechanisms. This work is completed.
  • Improvements in dynamic rate limiting algorithm to ensure fairness to legitimate traffic. (Estimated completion October 2022)
  • Improve existing proactive automatic communication process to notify customers more expeditiously. (Estimated completion October 2022)

How can we make our incident communications more useful?

Microsoft is piloting this “PIR” template as a potential replacement for our “RCA” (Root Cause Analysis) template.

You can rate this PIR and provide any feedback using our quick 3-question survey,